Concrete Slab Moisture Testing in Queensland and NSW, Australia.

Home > Concrete moisture testing

Concrete Subfloor Moisture Testing Southern Queensland and Northern Rivers Region, NSW, Australia.

ICRI Certified Concrete Slab Moisture Testing technitian.

Before installing any floor covering, it is critical to ensure the concrete slab or subfloor meets the required moisture standards. Excess moisture can cause flooring failures, adhesive breakdown, cupping, warping, mould growth, and costly repairs.

Professional moisture testing helps identify potential problems before installation and is often required by flooring manufacturers to maintain product warranties.

Flooring Types We Test For

We provide concrete slab moisture testing for all flooring types, including:

Industry-Compliant Testing

As an ICRI-certified concrete slab moisture testing technician, Matthew performs testing in accordance with ASTM standards and AS 1884:2021 requirements.

Testing is conducted using industry-approved methods to accurately determine the moisture condition of concrete slabs and subfloors. Results help builders, flooring installers, property managers, and homeowners confirm whether a slab is ready for flooring installation or requires further drying or remediation.

Why Moisture Testing Matters

  • Helps prevent flooring failures and expensive repairs
  • Supports compliance with manufacturer warranty requirements
  • Confirms suitability of concrete slabs before installation
  • Provides independent, professional test results
  • Reduces project delays and installation risks

Book Your Concrete Moisture Test

Whether you’re installing timber, hybrid, vinyl, laminate, carpet, or tile flooring, professional moisture testing provides the confidence that your concrete slab is ready for installation.

Contact Matthew today to arrange certified concrete slab moisture testing and ensure your flooring project starts on a solid foundation.

Call: 0491303162

ICRI concrete slab moisture testing technician
Subfloor moisture testing

Do all concrete slabs require moisture testing before installing flooring?

Yes! Every Concrete Subfloor Should Be Moisture Tested

It makes no difference whether a concrete slab is 28 days old or 28 years old—both the concrete and the plastic vapour barrier beneath it can deteriorate over time, allowing moisture-related problems to develop.

Australian Standard AS 1884:2021 requires moisture testing to determine whether a concrete subfloor is suitable for the installation of resilient floor coverings. Moisture conditions cannot be determined by appearance alone and must be verified using recognised testing methods.

Skipping moisture testing can lead to costly flooring failures, including adhesive breakdown, bubbling, blistering, cupping, mould growth, and premature floor covering replacement.

Don’t risk floor covering failure—test every concrete subfloor before installation.

Carpet floor Inspection

Wood Floor Inspection

Laminate Floor Inspection

Vinyl Floor Inspection

Hybrid Floor Inspection

Subfloor Moisture Test

Pre-installation Inspection

Professional Concrete Moisture Testing.

Moisture in concrete slabs, resulting in floor-covering failure, is a global multimillion-dollar problem. Engaging a certified moisture-testing technician before floor installation will prevent costly problems. Matthew provides ICRI-certified concrete slab moisture testing services for builders, floor installers, retailers, home, and business owners across Northern NSW and Southern Queensland, Australia.

Matthew Wilson

Floor Inspector

Matthew is an independent, certified floor inspector and concrete slab moisture testing technician. Matthew is dedicated to fair, unbiased floor inspections with a focus on accuracy, objectivity, and professionalism. Reports are based on facts, not opinion.

Certified Concrete Slab Moisture Testing in Queensland and NSW, Australia.

Call: 0491303162

Pre-installation moisture testing

Installing floor coverings over a new or existing concrete slab requires moisture testing per the manufacturer’s and industry installation guidelines. Matthew is certified to perform these ASTM F1869, F2170, F710, F2659, and F3191 tests on concrete slabs and substrates.

Post installation concrete slab moisture testing.

Elevated moisture within a concrete slab can cause numerous issues with floor coverings and is the major cause of failure. These issues can include buckling, curling, cupping, mould, etc. Testing for moisture under a floor requires an experienced technician.

Years Experience

Flooring projects

Floors installed

Floors refinished

Certified concrete moisture testing.
Floor Consultant and Training Services
National Wood Flooring Association
North American Laminate Flooring Association

When to engage a floor inspector?

25+

Years of flooring experience - Professional and certified Floor Inspector & Concrete Slab Moisture Testing Technician.

Floor Consultant & Inspector Training School is North America's most respected floor inspector training certification. Since 1988, the FCITS has been training flooring professionals and advancing their knowledge to become floor inspectors in both residential and commercial settings.

The National Wood Flooring Association, or NWFA, offers industry-accepted standards and accessible resources for floor inspectors to keep updated with current products and techniques concerning solid and engineered wood flooring.

The North American Laminate Flooring Association, NALFA dedicated solely to the laminate flooring industry since 1997. Its purpose is to identify and develop solutions that lead to the floor-covering industry's and its professionals' success.